PA66 Flame Retardant

EAG225V0B

EAG225V0B: 25% flame-retardant PA66 compound for electrical and structural molded parts requiring flame rating review. The recorded profile for this grade lists specific gravity 1.34, tensile stress 140 MPa, and HDT 240 degrees C. Confirm final suitability against the molded part and processing conditions.

Document Support
TDSSDSCOAREACHRoHS

REACH / RoHS support available upon request.

Grade Snapshot

Review the reference values before confirming this material for a molded part or document request.

Specific gravity
1.34
ISO 1183
Tensile stress
140 MPa
ISO 527
HDT 1.8 MPa
240 °C
ISO 75
Flammability
V-0 Class
UL 94, 0.8 mm

Core Selection Data

Reference Values for Early Screening

PropertyValueUnitTest Method
Specific gravity1.34ISO 1183
Tensile stress140MPaISO 527
Tensile modulus8300MPaISO 527
Flexural modulus7700MPaISO 178
Charpy impact strength(Notched) @ 23 °C7.8kJ/m2ISO 179/1eA
Heat deflection temperature (1.8 MPa)240°CISO 75

Core comparison values are shown here. Full property, processing, impact, electrical, and project-specific data are provided through TDS or project review.

Request Full TDS

Grade Characteristics

  • PA66 Flame Retardant compound direction
  • 25% filler or reinforcement reference
  • V-0 flammability reference
  • Final selection should be confirmed against part design and molding conditions

Typical Applications

  • Connectors
  • electrical housings
  • switches
  • bobbins
  • terminal blocks and other E&E components.

Material Evaluation Notes

This grade page is for preliminary material selection. For project evaluation, please confirm the application, processing method, mold development stage, cavity count, target dimensional requirement, target performance requirements, current reference grade, document requirements, and estimated volume.

Inquiry Preparation

Prepare a Grade Evaluation

Send the application, key performance requirements, mold stage, cavity count, dimensional concern, current material or reference grade, document needs, and estimated volume. These inputs identify the next grade, document, and sample steps for the project.