PA6 Glass Fiber Reinforced

EAG120

EAG120 is a 20% glass-fiber-reinforced PA6 grade with 125 MPa tensile stress, 6500 MPa flexural modulus, 5.5 kJ/m2 notched impact and 205 °C HDT at 1.8 MPa. Confirm final suitability against the molded part and processing conditions.

Document Support
TDSSDSCOAREACHRoHS

REACH / RoHS support available upon request.

Grade Snapshot

Review the reference values before confirming this material for a molded part or document request.

Specific gravity
1.29
ISO 1183
Tensile stress
125 MPa
ISO 527
HDT 1.8 MPa
205 °C
ISO 75
Flammability
HB Class
UL 94, 0.8 mm

Core Selection Data

Reference Values for Early Screening

PropertyValueUnitTest Method
Specific gravity1.29ISO 1183
Tensile stress125MPaISO 527
Flexural modulus6500MPaISO 178
Charpy impact strength(Notched) @ 23 °C5.5kJ/m2ISO 179/1eA
Heat deflection temperature (1.8 MPa)205°CISO 75

Core comparison values are shown here. Full property, processing, impact, electrical, and project-specific data are provided through TDS or project review.

Request Full TDS

Grade Characteristics

  • Against EAG120U at the same listed glass-fiber content, EAG120 has a slightly higher published flexural modulus, while EAG120U publishes higher tensile stress, flexural strength, notched impact and HDT.
  • 20% filler or reinforcement reference
  • HB flammability reference

Typical Applications

  • Structural housings
  • brackets and molded supports evaluated around a 20% glass-fiber PA6 starting point and a 6500 MPa published flexural modulus.

Material Evaluation Notes

Compare both 20% grades using the same specimen conditioning and test methods, then confirm flow, fiber orientation, warpage and mechanical performance in the intended mold.

Inquiry Preparation

Prepare a Grade Evaluation

Send the application, key performance requirements, mold stage, cavity count, dimensional concern, current material or reference grade, document needs, and estimated volume. These inputs identify the next grade, document, and sample steps for the project.